Technical data
01| Nominal size | DN25 – DN1000 · custom sizes available |
|---|---|
| Pressure rating | PN6 – PN25 · Class 150 |
| Service temperature | NBR −30 °C … +100 °CEPDM −50 °C … +150 °CFKM −20 °C … +200 °CSilicone (VMQ) −55 °C … +200 °CPTFE −196 °C … +260 °CMetal −196 °C … +538 °C Depends on the seal option; may be narrower depending on body and trim material. Exact value in the quotation. |
| Standard | DIN · JIS · ANSI |
| Connection | EN 1092-1/BEN 1092-1Flanges and their joints — circular flanges, PN designated · Part 1: steel flanges DIN 2501DIN 2501Flanges — connection dimensions (former DIN series) |
| Test | TS EN 12266-1TS EN 12266-1Industrial valves — testing of valves · Part 1: pressure tests |
| Operation | Spring-loaded or free (gravity-acting) disc |
| Seal | EPDM · NBR · FKM (Viton) · Silicone · PTFE |
The standards listed apply to stocked products. Contact us for other standards.
Material
02A wide range of materials sets the wafer check valve apart from Emsal's other check valves. Materials not listed can be supplied as custom manufacturing.
| Body | |
|---|---|
| Disc | |
| Lock, bolts | |
| Seal | |
| Coating for Fe-C materials |
Pressure drop
03- Pressure drop
- —
- Kv
- —
- Min. cracking pressure · horizontal, without spring
- —
The cracking pressure is calculated by Emsal for a horizontal line and a disc without spring. At least 0.3 bar back pressure is required for tight shut-off.
Features
04Design
- Opens in the flow direction; closes against back pressure by spring or by its own weight
- Mounted directly between flanges
- Small size, low weight
Advantages
- Takes up little space
- Low pressure drop
- Fast closing — reduced risk of water hammer
- Easy installation, low maintenance
Applications
- HVAC and water treatment
- Process lines, pump discharges
- Chemical and petrochemical
- Fire fighting
- Energy, marine
Considerations
- Size matched to flange type and diameter
- Spring-loaded type in horizontal lines
- Seal suited to the medium
- Install according to the flow direction
Position in the line
05 · P&IDThe check valve is usually installed at the pump discharge, upstream of the isolation valve: when the pump stops, it prevents the line from draining back and the pump from running in reverse.
See it in the process line on the home page →
Accessories
06Downloads
07Open datasheet
Thank you, we have received your details.
Open sample