Technical data
01| Nominal size | DN4 – DN200 |
|---|---|
| Pressure rating | PN6 – PN420 |
| Standard | DIN |
| Connection type | Flanged |
| End connection standard | EN 1092-1EN 1092-1Flanges — steel flanges, PN designated ISO 7005-1ISO 7005-1Metallic flanges — steel flanges |
| Test | ISO 11631:1998 |
The standards listed apply to stocked products. Contact us for other standards.
Features
02Operation
- The fluid turns the turbine blades as it passes through the rotor.
- The rotational speed of the turbine is proportional to the flow rate.
- Magnetic or optical sensors detect the rotation of the rotor, and the electronics convert the signals into a flow rate.
Advantages
- High accuracy: down to ±0.5% error, especially in systems with steady flow.
- Wide temperature and pressure range: models with steel bodies and precision bearings can also be used in harsh conditions.
- Analogue & digital outputs: easy integration with SCADA and PLC systems.
- Cost-effective: more economical than other high-tech flow meters.
Applications
- Fuel flow control
- Measurement of low-viscosity chemicals
- Cooling water and glycol control
- Dosing of pure water and solutions
Considerations
- The fluid must be clean and free of particles; solids can wear the turbine.
- Calibration is required; periodic recalibration is recommended to maintain accuracy over time.
- Flow direction and correct installation matter; reversed installation causes measuring errors.
Downloads
03DatasheetPDF · TR · dimension and weight table
IN PREPARATION
IN PREPARATION
CAD modelSTEP · DXF · by nominal size
IN PREPARATION
IN PREPARATION
3.1 certificate samplePDF · EN 10204 · TR/EN
Open sample
Open sample